TA2000

A key point of the TA2000 control unit Tacóra series is the dual configurability (conventional and analogue addressable), ideal for mixed or purely conventional solutions with articulated structures such as the integration of an FYRA analogue loop into existing conventional systems.

TA2000 satisfies every needs with the innovative system’s structure: through the appropriate modules is possible to customize the input lines, expand zones up to 12 conventional and 1 FYRA analogue/addressable loop, to control the control unit via TCP/IP or via GSM and to manage the extinguishing systems. The intuitive display provides an easy interaction with the control unit.

TA2000 is certified CPR 305/2011 EN 54-2, EN 54-4, EN54-13, EN 54-21 (with 4G and LAN optional modules), EN 12094-1 (with extinguished module mod. EXTING).

browser
The firmware of the TACÓRA control panels can be updated independently by an authorized installer: contact us
  • Product code

    ICCTA0103800

    Conventional zones

    4 conventional zones configurable as:

    Input for conventional absorption detectors with 4K7 Ohm balancing resistance

    Open collector output

    Pull-up input for connection to a open-collector output device

    Balanced input

    4 - 20mA input

    Expansions

    Expandable to 12 conventional zones with 1 TAEXP10 expansion board (optional) and with 1 analogue-addressable loop expansion board analogue-addressable TALOOP (optional) to allow a mixed configuration

    Call-points zones

    1 zone absorption detectors/call points with 4K7 Ohm balanced resistance

    Outputs

                    1 balanced supervised output for alarm, PTC protected

    1 RELAY NO/C/NC output for general fault

    1 RELAY NO/C/NC output for pre alarm

    2 RELAY NO/C/NC outputs configurable

    1 DC24V output for users, PTC protected

    1 resettable DC24V output for users, PTC protected

    4 optional relay outputs with TAREL24 module

    1 RS485 for 2 TAREPEATER connection

    USB

    1 USB connector

    Connectors for
    optional modules

    MDGSME GSM module for sending alarm / control panel status reports via SMS and interfacing to the e-Connect platform

    MD4GE for sending alarm / control panel status reports via SMS, interfacing to the e-Connect platform and connecting to surveillance institutes via SIA IP Reporting protocol (TCP-2007) (in combination with MDLAN)

    TAREL24 board with 4 programmable relay outputs

    LAN MDLAN board for the Ethernet connection

    EXTING extinguishing module 1 zone

    User interface

    Multi-colour backlight graphic display, keypad and LED indicators

    Event storing

    Storage up to 2000 events

    Functions

    Automatic change of the backlight display color depending on the control unit status

    Evacuation

    Acoustic devices silencing

    Control unit restore

    Day/night mode

    Zones, devices and modules exclusion

    Functional test on control unit, inputs and outputs

    Time slot configuration and personalization

    Protection class

    IP30

    Power supply unit

    Internal mod.  AL75LRS29V0 (75 W)

    Batteries

    Batteries placed internally 2x12V/18Ah (optional). Power supply system with battery charge control and charge unbalance NTC1 and NTC2 optional batteries temperature control

    Operating temperature

    -5°/+40° 93% UR

    Dimensions/weight

    W 390 x H 390 x D 99mm, 6 Kg

    Power consumption

    80mA idle state

    Power supply

    AC230V

    Certifications

    CPR 305/2011 EN 54-2, EN 54-4, EN54-13, EN 54-21 (with 4G and LAN optional modules), EN 12094-1 (with extinguished module mod. EXTING).

    Product code

    ICCTA0103800

  • Centrali Antincendio serie Tacóra

    1101.66 KB

    • TACÓRA

      Brochure delle centrali antincendio convenzionali della serie Tacóra

    Tacóra series control units

    1202.43 KB

    • TACÓRA

      Tacóra series conventional control units brochure

  • Software Configuration

    Step-by-step guide

    • Guida step-by-step
      Model
      31/05/2019
       
    • Step-by-step guide
      Model
      31/05/2019
       
    • Guide étape par étape
      Model
      03/06/2024
       

    Datasheet

    • Foglio tecnico
      Model
      13/10/2014
       
    • Datasheet
      Model
      13/10/2014
       

    Product Description

    • Descrizioni Capitolato
      Model
      13/01/2014
       
    • Product Description
      Model
      30/05/2016
       

    User Manual

    Quick Guide

    • Quick Guide
      Model
      17/12/2024
       
    • Quick Guide
      Model
      17/12/2024
       
    • Quick Guide
      Model
      17/12/2024
       

    Technical Manual

    • Manuale Tecnico
      Model
      17/10/2023
       
    • Technical Manual
      Model
      17/10/2023
       

    Programming Manual

    • Manuali di Programmazione
      Model
      16/12/2024
       
    • Programming Manual
      Model
      16/12/2024
       

    CE - DoP

    • CE - DoP
      Model
      24/05/2024
       
    • CE - DoP
      Model
      24/05/2024
       

    Notified Body

    • Ente Notificato
      Model
      11/09/2024
       
    • Notified Body
      Model
      11/09/2024
       

    Other

  • Product Description

    • Dichiarazione Conformità e prestazione
      Model
      13/01/2014
       

    User Manual

    Quick Guide

    • Quick Guide
      Model
      17/10/2023
       
    • Quick Guide
      Model
      15/11/2018
       
    • Quick Guide
      Model
      06/06/2016
       
    • Quick Guide
      Model
      22/07/2020
       

    Technical Manual

    • Manuale Tecnico
      Model
      15/11/2018
       
    • Technical Manual
      Model
      15/11/2018
       
    • Manuale Tecnico
      Model
      09/03/2016
       
    • Technical Manual
      Model
      13/01/2014
       
    • Manuale Tecnico
      Model
      13/01/2014
       
    • Manuale Tecnico
      Model
      13/01/2014
       
    • Manuale Tecnico
      Model
      13/01/2014
       
    • Manuale Tecnico
      Model
      13/01/2014
       
    • Manuale Tecnico
      Model
      13/01/2014
       
    • Manuale Tecnico
      Model
      13/01/2014
       
    • Manuale Tecnico
      Model
      13/01/2014
       
    • Manuale Tecnico
      Model
      13/10/2014
       

    Programming Manual

    • Manuali di Programmazione
      Model
      03/05/2022
       
    • Programming Manual
      Model
      03/05/2022
       
    • Manuali di Programmazione
      Model
      23/11/2021
       
    • Programming Manual
      Model
      23/11/2021
       
    • Manuali di Programmazione
      Model
      14/02/2019
       
    • Development Manual
      Model
      21/02/2019
       
    • Manuali di Programmazione
      Model
      15/11/2018
       
    • Development Manual
      Model
      15/11/2018
       

    Software Manual

    • Manuale Software
      Model
      02/12/2014
       
    • Software Manual
      Model
      02/12/2014
       

    Software

    • Software
      Model
      13/01/2014
       
    • Software
      Model
      13/01/2014
       
    • Software
      Model
      02/12/2014
       
    • Software
      Model
      08/06/2016
       
    • Software
      Model
      13/10/2014
       
    • Software
      Model
      13/10/2014
       
    • Software v.3.0.4
      Model
      13/01/2014
       
    • Software 3.0.4
      Model
      13/01/2014
       
    • Software
      Model
      13/01/2014
       
    • Software 2.1.2
      Model
      13/01/2014
       
    • Software
      Model
      13/01/2014
       
    • Software
      Model
      13/01/2014
       

    Certificate of conformity

    • Certificato di conformità alla direttiva
      Model
      13/01/2014
       

    Other

    • ICCTA0103800
      Centrale incendio convenzionale/analogico indirizzata 4 zone epandibili a 12 + 1 loop opzionale new case USB
    • ICCTA0100300
      Centrale incendio convenzionale/analogico indirizzata 4 zone esp. 44
    • ICCTA0100301
      4 zones exp. to 44 zones analogue addressable/ conventional fire detection control unit -ENGLISH VERSION
    • ICCTA0101500
      Centrale incendio convenzionale/analogico indirizzata 4 zone esp. 44 New Case
    • ICCTA0101501
      4 zones exp. to 44 zones new case analogue addressable/ conventional fire detection control unit -ENGLISH VERSION
    • ICCTA0102300
      Centrale incendio convenzionale/analogico indirizzata 4 zone esp. 44 versione Sicurezza Intrinseca
    • ICCTA0102301
      4 zones exp.to 44 zones new case analogue addressable/conventional fire detection control unit intrinsically safe version - ENGLISH VERSION
    • ICCTA0102700
      Centrale incendio convenzionale/analogico indirizzata 4 zone epandibili a 12 + 1 loop opzionale new case
    • ICCTA0102701
      Analogue addressable/conventional fire detection control unit 4 zones exp.to 12 zones+1 optional loop new case ENGLISH VERSION
    • ICCTA0102800
      Centrale incendio convenzionale/analogico indirizzata 4 zone epandibili a 12 + 1 loop opzionale new case sicurezza intrinseca
    • ICCTA0102801
      Analogue addressable/conventional fire detection control unit 4 zones exp. to 12 zones + 1 optional loop new case intrinsically safe version - ENGLISH VERSION
    • ICCTA0103801
      Analogue addressable/ conventional fire detection control unit 4 zones exp. to 12 zones + 1 optional loop new case USB ENGLISH VERSION
    • ICCTA0104000
      Centrale incendio convenzionale/analogico indirizzata 4 zone epandibili a 12 + 1 loop opzionale new case sicurezza intrinseca USB
    • ICCTA0104001
      Analogue addressable/ conventional fire detection control unit 4 zones exp. to 12 zones + 1 optional loop new case intrinsically safe version USB ENGLISH VERSIO

Active Products