FIRERAY3000

FIRERAY3000 is an End-to-End infrared optical beam smoke detector with operative range 5-120m. It is the ideal solution for the protection of large areas where the use of technologies with punctiform traditional detection may prove insufficient. The equipment includes a transmitter unit, a receiver unit and a controller with display. 

The installation of FIRERAY3000 system is very easy: both the detector head, transmitter and receiver, have integrated alignment thumbwheels. In addition , there is a integral laser alignment in the receiver unit. FIRERAY3000 system has the AGC function (automatic gain control for drift compensation)

 The system can be extended with the use of FIRERAY3000ES optional kit (kit with one transmitter unit and one receiver units). In fact, the controller is able to manage two pairs of TX/RX units, signalling separately alarm and fault events for each pair. FIRERAY3000 is certified CPR 305/2011 (ex CPD 89/106/EEC certification) EN54-12 and VDS EN54-12

  • Type
    • End-to-End infrared optical beam smoke detector
    Parts supplied
    • 1 transmitter unit, 1 receiver unit and 1 controller supplied
    Range
    • 5-120m
    Expansion
    • The system can be extended with the use of FIRERAY3000ES optional kit (kit with one transmitter unit and one receiver units).
    Controller
    • The controller can manage up to 2 pairs of TX/RX heads
    Lsser
    • Integral laser alignment in receiver unit
    Function AGC
    • Automatic gain control (AGC) for drift compensation
    LED indication
    • LED on controller and receiver unit
    Response sensitivity/Threshold
    • Adjustable from 10% to 60%
    Delay to alarm/fault
    • Adjustable from 2 sec to 30 sec
    Operating temperature
    • -10°C / +55°C, 93% Relative Humidity (non-condensing)
    IP class
    • IP54
    Controller dimensions and weight
    • W 203 x H 124 x D 71,5 mm, 606 gr
    Heads dimensions and weight
    • W 78 x H 77 x D 161mm, 207 gr
    Controller power consumption 
    • 14mA (with 1 or 2 receivers)
    Transmitter unit power consumption
    • 8mA
    Range power supply
    • DC12V to DC36V ±10%.
    Certification
    • Certified CPR 305/2011 (ex CPD 89/106/EEC certification) EN54-12
    • VDS EN54-12
  • Datasheet

    • Foglio tecnico
      Model
      09/04/2015
       
    • Datasheet
      Model
      09/04/2015
       

    Product Description

    • Descrizioni Capitolato
      Model
      09/04/2015
       
    • Descrizioni Capitolato
      Model
      09/04/2015
       

    Technical Manual

    • Manuale Tecnico
      Model
      13/01/2014
       
    • Manuale Tecnico
      Model
      13/01/2014
       

    Certificate of conformity

    • Certificato di conformità alla direttiva
      Model
      13/01/2014
       
    • Certificato di conformità alla direttiva
      Model
      13/01/2014
       

    Other

    • Addendum
      Model
      03/08/2016
       
    • Addendum
      Model
      03/08/2016
       
    • RLFIR0200100
      Rivelatore lineare di fumo a barriera con controller 120mt EN54-12

Active Products