Installation |
On any type of wall, including brick, tuff and reinforced concrete walls. Also suitable for the protection of safes, ATMs and continuous boxes. Does not require fixing plate for proper sensor operation. In case of installation on uneven walls or to replace GM730 or KSM412, optional universal fixing plate (RMIBRK) is available. Cable entry on each side and internal space for wiring |
Coverage area (The detector varies its performance depending on the material of the protected structure.) |
Up to 46 mq |
Setup |
Calibration and configuration of the system occurs by means of RMISETUP app for iOS/Android devices and the Wi-Fi dongle connected to the detector (see RMIDNG technical datasheet). |
Functions |
Sophisticated analysis algorithms for recognizing different techniques of attack on the protected structure: break-in (weak shocks), breakage (strong shocks), smashing (very strong single shocks), and continuous vibration (cutting or drilling with power tools). Anti-removal and anti-opening tamper, thermal tamper, periodic programmable self-test, operational test |
Connection |
POWER SUPPLY; OPERATIONAL TEST and ARM MEMORY; ALARM OUTPUT, SELF-TEST FAILED OR OPERATIONAL TEST SUCCESSFUL, LOW POWER SUPPLY; TAMPER |
Material |
White ABS |
Dimensions |
W 89 × H 89 × D 20 mm |
Weight |
53 g |
Power supply |
DC12V (from 8V to 16V) |
Current |
20 mA 50 mA max in calibration phase |
Operating temperature |
-20 / +70 °C |
IP protection |
IP40 |
Certification |
EN 50131-2-8 grade 3, environmental class II |