TRES01

TRES01 is a triple technology detector (MW + 2IR) capable of accurate analysis of the received signal, using sophisticated algorithms and the most updated and available microprocessors. TRES01 features an operative range up to 15m and anti-blinding, anti-masking and under-crawl functions.

One of the key points of this detector is the use of a digital double IR which combined with the MW gets very high immunity to noise and detection accuracy.

The pleasant design, the reduced dimensions and the possibility of bracket mounting for wall and angle installation make this detector suitable in any type of environment. TRES01 is certified IMQ-Allarme EN50131-2-4 grade 3, environmental class II.

 
  • MW section
    • DRO planar antenna with pulsed operative system
    • Sensitivity: dipswitch for selection between minimum 8 pulses and maximum 4 pulses with 5s waiting (unique dipswitch for MW and IR)
    • Range from 3m to 15m adjustable  +/-20%
    • Coverage area:  95° horizontal, 60° vertical
    • Timings: single alarm with confirmation waiting from the IR sections for 10s (with AND operations), direct alarm to general relay for OR
    IR section
    • High sensitivity digital PIR sensor
    • Sensitivity: 2 x 18 zones on 4 floors
    • Range: 15m with standard height fixing of 2.1 m
    • Coverage area: 81°
    • Sensibilità: dipswitch for selection between minimum 4 pulses and maximum 2 pulses with 10s waiting
    • Temporizzazioni: single alarm with confirmation waiting from the MW sections for 5s (with AND operations), direct alarm to general relay for OR operations
    Filters

    IR lens with protection from white light

    LED
    • MW section
    • IR section
    • Alarm status
    • Failures
    • Anti-masking
    • Anti-blinding
    Functions
    • IR section with 2 high sensitivity digital PIR sensors for false alarms reduction and insect entrance
    • Anti-blinding circuit on IR section
    • Anti-masking circuit on MW section
    • Sensitivity selection settable through dipswitch between minimum and maximum
    • AND/OR operation settable through dipswitch
    • 3D function
    • Fresnell lens and lower lens with under-crawl device ultrasonic and non-replaceable welded
    • Alarm relay for protection against external magnets
    • Protection against noise applied to the power terminals, also the alarm relay has output contacts with a serial resistance
    Protection class IP3X
    Operating temperature -10°C / +55°C , 93 % U.R.
    Dimensions/weight
    • W 64 - H 110 - D 48 mm
    • 109 g
    Power consumption
    • 19mA idle status
    • 21mA alarm status
    • 17mA stand-by with MW esclusion
    Power supply 12Vdc
    Certification Certified IMQ-Allarme EN50131-2-4 for the grade 3, environmental class II
    Parts supplied Screws, dowels, S4 screw and dowel, technical manual
  • Sensori tripla tecnologia serie TRES

    475.49 KB

    • TRES1

      Depliant dei sensori a tripla tecnologia della serie TRES

    TRES series detectors

    458.03 KB

    • TRES1

      Brochure of TRES series triple technology detectors

    Sensori antintrusione EL.MO.

    3688.43 KB

    • sensori antintrusione 2017

      Brochure della gamma di sensori antintrusione EL.MO.

    EL.MO. intrusion detectors

    3876.41 KB

    • sensori antintrusione 2017

      EL.MO. intrusion detectors brochure

  • Datasheet

    • Foglio tecnico
      Model
      11/04/2022
       
    • Datasheet
      Model
      11/04/2022
       

    Product Description

    • Descrizioni Capitolato
      Model
      11/04/2022
       

    Technical Manual

    • Manuale Tecnico
      Model
      28/02/2019
       
    • Manuale Tecnico
      Model
      04/06/2024
       
    • Technical Manual
      Model
      28/02/2019
       

    CE - DoP

    • CE - DoP
      Model
      07/09/2023
       
    • CE - DoP
      Model
      07/09/2023
       

    Notified Body

    • Ente Notificato
      Model
      07/09/2023
       
    • Notified Body
      Model
      07/09/2023
       
  • Technical Manual

    • Manuale Tecnico
      Model
      13/10/2014
       
    • Manuale Tecnico
      Model
      13/01/2014
       
    • Technical Manual
      Model
      11/11/2016
       
    • Manuale Tecnico
      Model
      13/01/2014
       
    • RCRTT0101600
      Sensore Tripla Tecnologia MW+2IR 15mt antimascheramento antiaccecamento antistrisciamento IMQ EN50131 new case
    • RCRTT0100100
      Sensore Tripla Tecnologia 15mt antimascheramento antiaccecamento antistrisciamento EN50131
    • RCRTT0100400
      Sensore Tripla Tecnologia 9,9GHZ 15mt antimascheramento antiaccecamento antistrisciamento EN50131
    • RCRTT0100700
      Sensore Tripla Tecnologia 15mt antimascheramento antiaccecamento antistrisciamento IMQ EN50131
    • RCRTT0101000
      Sensore Tripla Tecnologia MW+2IR 15mt antimascheramento antiaccecamento antistrisciamento IMQ EN50131 new case
    • RCRTT0101100
      Sensore Tripla Tecnologia MW+2IR 15mt antimascheramento antiaccecamento antistrisciamento IMQ EN50131 new case 9,9 GHz
    • RCRTT0102500
      Sensore Tripla Tecnologia MW+2IR 15mt antimascheramento antiaccecamento antistrisciamento IMQ EN50131 new case colore nero
    • RCRTT0102600
      Sensore Tripla Tecnologia MW+2IR 15mt antimascheramento antiaccecamento antistrisciamento IMQ EN50131 new case 9,9 GHz colore nero
    • RCRTT0102700
      Sensore Tripla Tecnologia MW+2IR 15mt antimascheramento antiaccecamento antistrisciamento IMQ EN50131 new case
    • RCRTT0102800
      Sensore Tripla Tecnologia MW+2IR 15mt antimascheramento antiaccecamento antistrisciamento IMQ EN50131 new case 9,9 GHz
    • RCRTT0102900
      Sensore Tripla Tecnologia MW+2IR 15mt antimascheramento antiaccecamento antistrisciamento IMQ EN50131 new case colore nero
    • RCRTT0103000
      Sensore Tripla Tecnologia MW+2IR 15mt antimascheramento antiaccecamento antistrisciamento IMQ EN50131 new case 9,9 GHz colore nero