FX/10

The FX/10 is a sophisticated analogue-addressable fire detection control unit able to manage 1 loop with AS or Evolution or IE protocol.

The FX/10 control unit is suitable for medium-large installation (such as hotels, shopping malls, industries) thanks to the high performance, the fast installation and the easy management.

FX series control units offers a lot of extensions thanks to the possibility to connect synoptic repeater and remote displays.

  • Loop
    • 1
    Connectable devices
    • Max. 254 devices on the loop
    Protocols
    • AS (with FX/EXP01 module)
    • Evolution (with FXEXPEV module)
    • IE (with FX/EXPIE module)
    Zones
    • 40, not expandable.
    Dispaly and LED
    • Programming keyboard
    • LED indicators for signalling and operating status
    • LCD display for visualization and programming
    • LED on mainboard for power supply, F2, F3, F4 fuses fault.
    Relays
    • RELAY 1 alarm relay and RELAY 2  with contacts in change at 8A at AC250V
    Connection terminal on main board for
    • 1 supervised output freely programmable for BELL,
    • RELAY 1 output for FAULT event with C - NA – NC contacts,
    • RELAY 2 output FIRE ALARM that can be programmed to signal events with C-NO-NC contacts,
    • LOAD DC24V output.
    • RS-485 output on FX10485 optional board to manage peripherals as: power supply units, repeater panels and  synoptic repeater
    Connectors on main board for:
    • 1 optional loop expansion board  (choose from FX/EXP01, FXEXPEV or FXEXPIE),
    • 1 FX10485 serial interface board (optional),
    • 1 optional ETRLAN board,
    • For power cable from mains transformer secondary winding,
    • For optional board to view FX/EXP10 40 zones,
    • Minidin FIRMWARE connector  to download firmware.
    • Minidin MODEM-PC connector to connect the indicated devices,
    • Minidin PRINTER connector to connect PRT serial printer
    Functions
    • Management of inputs and output devices through logic events, system events
    • Management of outputs devices through logic events, system events and pattern
    • Definition of filters for management of events memory and printing process;
    • Weekly Programmer with Day/Night function
    • Date/time setup and daylight saving time switch;
    • Detectors check
    • Delay mode
    • Sensitivity with thresholds that can be programmed
    • by alarm, pre-alarm, and maintenance
    • Self-learning of loop devices with double address identification
    • Maintenance management with percent parameters of detectors, alarm type and print
    Arrangements
    • Cable with connector to connect and manage several power units, FXC72H cable required (optional).
    • Cable with NTC to fix directly on one of the batteries housing to control current supply related to internal temperature.
    Operating temperature
    • -5 / +40°C, 93% U.R.
    Dimensions and weight
    • W 325 x H 304 x D 133 mm, 5Kg
    Protection class
    • IP3X
    Power consumption
    • From network: 350mA @ AC 230 V
    • Main board: 120mA @ DC 24 V
    • FX/EXP01 loop board: 10 mA @ DC 24 V without detectors , 60 mA @ DC 24 V with 254 connected detectors (calculated with smoke sensors).
    • FXEXPEV loop board: 75 mA @DC 24 V without detectors, 150 mA @ DC 24 V with 254 connected detectors (calculated with smoke sensors).
    • FXEXPIE loop board: 25 mA @DC 24 V without detectors,165 mA @ DC 24 V with 254 connected detectors (calculated with smoke sensors).
    Power supply
    • AC 230 V, 50Hz
    • DC 24 V power supply unit included
    • Batteries: 2 x 7Ah/DC 12 V mod. B712G
    Certification
    • Certified CPR 305/2011 (e CPD 89/106/CEE certification) EN54-2 and EN 54-4
    Parts supplied
    • Connection cable in series of the buffer batteries, technical manual, user's manual, CD with WINFIRE/STD 4.x browser.
  • Software Configuration

    Datasheet

    • Foglio Tecnico
      Model
      23/03/2015
       
    • Datasheet
      Model
      24/03/2015
       

    Product Description

    • Descrizione Capitolato
      Model
      13/10/2014
       
    • Product description
      Model
      13/10/2014
       

    User Manual

    Technical Manual

    • Manuale Tecnico
      Model
      12/10/2015
       

    Programming Manual

    • Manuali di Programmazione
      Model
      12/10/2015
       

    Software Manual

    • Manuale Software
      Model
      19/02/2015
       

    Software

    • Software
      Model
      22/10/2021
       

    CE - DoP

    • CE - DoP
      Model
      13/06/2017
       
    • CE - DoP
      Model
      13/06/2017
       

    Notified Body

    • Ente Notificato
      Model
      13/06/2017
       
    • Ente Notificato
      Model
      13/06/2017
       

    Other

  • Software

    • Software
      Model
      25/09/2017
       
    • Software
      Model
      25/09/2017
       
    • Software
      Model
      12/10/2015
       
    • Software
      Model
      01/07/2015
       
    • Software
      Model
      01/07/2015
       
    • Software
      Model
      01/07/2015
       
    • CIFX00100700
      Centrale antincendio analogico indirizzato ad 1 loop
    • CIFX00100701
      1 Loop Analogue Addressable fire detection control panel - ENGLISH VERSION
    • CIFX00100702
      1 Loop Analogue Addressable fire detection control panel - CROATIAN VERSION
    • CIFX00100703
      1 Loop Analogue Addressable fire detection control panel - SLOVENIAN VERSION
    • CIFX00100704
      1 Loop Analogue Addressable fire detection control panel - GERMAN VERSION
    • CIFX00100706
      1 Loop Analogue Addressable fire detection control panel - SPANISH VERSION

Active Products